Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Imaging Science in Dentistry ; : 229-234, 2019.
Article in English | WPRIM | ID: wpr-764002

ABSTRACT

Central odontogenic fibroma (COF) is defined as a fibroblastic odontogenic tumor characterized by varying density of the tooth epithelium. It is an extremely rare benign neoplasm that occurs in the maxilla and the mandible; only a few reports of COF are available in the literature. Diagnosis of the lesion based only on the radiological features of COF is difficult due to variation in the findings regarding this condition. This report describes 2 clinical cases of middle-aged women with COF. Clinical examination revealed palatal mucosal depression; additionally, oral examination, as well as panoramic radiographs, intraoral radiographs, and computed tomography scans, revealed severe root resorption. This report highlights the clinical and radiological imaging features of COF, with the goal of enabling straightforward differential diagnosis of the lesion by the clinician and thereby appropriate treatment of the patient.


Subject(s)
Female , Humans , Depression , Diagnosis , Diagnosis, Differential , Diagnosis, Oral , Epithelium , Fibroblasts , Fibroma , Mandible , Maxilla , Odontogenic Tumors , Root Resorption , Tooth
2.
Imaging Science in Dentistry ; : 301-306, 2019.
Article in English | WPRIM | ID: wpr-785810

ABSTRACT

PURPOSE: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases.MATERIALS AND METHODS: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow.RESULTS: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan.CONCLUSION: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.


Subject(s)
Humans , Catheters , Salivary Glands , Sialography , Ultrasonography , Vasodilation
3.
Imaging Science in Dentistry ; : 111-119, 2018.
Article in English | WPRIM | ID: wpr-740372

ABSTRACT

PURPOSE: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. MATERIALS AND METHODS: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. RESULTS: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements (P < .05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. CONCLUSION: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.


Subject(s)
Anthropometry , Cone-Beam Computed Tomography , Dimensional Measurement Accuracy , Imaging, Three-Dimensional
4.
Imaging Science in Dentistry ; : 59-65, 2018.
Article in English | WPRIM | ID: wpr-740359

ABSTRACT

Osseointegrated implants are now commonplace in contemporary dentistry. However, a number of complications can occur around dental implants, including peri-implantitis, maxillary sinusitis, osteomyelitis, and neoplasms. There have been several reports of a malignant neoplasm occurring adjacent to a dental implant. In this report, we describe 2 such cases. One case was that of a 75-year-old man with no previous history of malignant disease who developed a solitary plasmacytoma around a dental implant in the left posterior mandible, and the other was that of a 43-year-old man who was diagnosed with squamous cell carcinoma adjacent to a dental implant in the right posterior mandible. Our experiences with these 2 cases suggest the possibility of a relationship between implant treatment and an inflammatory cofactor that might increase the risk of development of a malignant neoplasm.


Subject(s)
Adult , Aged , Humans , Carcinoma, Squamous Cell , Dental Implants , Dentistry , Mandible , Maxillary Sinus , Maxillary Sinusitis , Mouth Neoplasms , Osteomyelitis , Peri-Implantitis , Plasmacytoma
5.
Imaging Science in Dentistry ; : 165-174, 2017.
Article in English | WPRIM | ID: wpr-157678

ABSTRACT

PURPOSE: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. MATERIALS AND METHODS: Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. RESULTS: The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. CONCLUSION: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.


Subject(s)
Americas , Colloids , Cone-Beam Computed Tomography , Imaging, Three-Dimensional , Seoul
SELECTION OF CITATIONS
SEARCH DETAIL